Message Overview:
Message Description:
The amber 'R WING A/I LOW TEMP' CAS message will appear when a low temperature condition is sensed at the wing and no other fail messages from the air system are present. If other failures from the air system are present, the R WING ANTI-ICE FAIL message will overwrite the R WING A/I LOW TEMP message.
Possible Causes:
- Integrated Air System Controller (IASC1)
- Data Concentrator Unit (DCU) (A14)
- Wing Leading Edge Temperature Sensors
- Right Anti-Ice Valves
- Cross-flow Anti-Ice Valves
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-72-0348 - AS907 Engine Diffuser Seal and Anti-Ice Valve
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Operational Test of the Integrated Air System (IAS) Controller | AMM 21-31-01-710-801 |
| Operational Test of the Leading-Edge Temperature Sensors | AMM 30-11-00-710-801 |
| Removal of the Inboard Leading-Edge Temperature Sensor | AMM 30-11-01-000-801 |
| Installation of the Inboard Leading-Edge Temperature Sensor | AMM 30-11-01-400-801 |
| Removal of the Outboard Leading-Edge Temperature Sensor | AMM 30-11-03-000-801 |
| Installation of the Outboard Leading-Edge Temperature Sensor | AMM 30-11-03-400-801 |
| Removal of the Wing Cross-Bleed Valve | AMM 30-11-05-000-801 |
| Installation of the Wing Cross-Bleed Valve | AMM 30-11-05-400-801 |
| Deactivation of the Wing Cross-Bleed Valve | AMM 30-11-05-040-801 |
| Activation of the Wing Cross-Bleed Valve | AMM 30-11-05-440-801 |
| Removal of the Wing Cross-Bleed Valve Sense Line | AMM 30-11-07-000-801 |
| Installation of the Wing Cross-Bleed Valve Sense Line | AMM 30-11-07-400-801 |
| Removal of the Anti-Ice Control Panel | AMM 30-11-09-000-801 |
| Installation of the Anti-Ice Control Panel | AMM 30-11-09-400-801 |
| Removal of the Wing Anti-Ice Valve | AMM 30-12-01-000-801 |
| Installation of the Wing Anti-Ice Valve | AMM 30-12-01-400-801 |
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Perform AMM to verify the proper operation of the wing leading edge temperature sensors.
- If any of the sensors fail the above check, replace the sensor.
- Entering the system diagnostics LRU tests for IASC 1B and 2B will allow viewing of the wing temperature sensors.
- Selecting the wing anti-ice sensor status will bring up the individual temperature sensors.
- With wing heat on, the system will try and regulate the inner sensors to 54°C. The AMM has this checked at idle and power settings assuring that the left, right, and cross-flow ANTI-ICE valves operate correctly.
- Displayed will be the following parameters on the sub system page:
- Left Inboard Leading Edge Temperature °C
- Left Outboard Leading Edge Temperature °C
- Right Inboard Leading Edge Temperature °C
- Right Outboard Leading Edge Temperature °C