01/27/21
Message Overview:
Message Description:
The cyan 'WING SOURCE-XBLEED' advisory CAS message indicates the wing cross-bleed valve is detected failed in the 'OPEN' position.
- Component status can be viewed through the MDC system diagnostics IASC channel B LRU test.
Possible Causes:
- None
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
- Check wiring between the Wing Cross Valve and the DCU. Disconnect MPE10P1 from the Wing Cross Valve and check on pin 3 if the is no ground detected using an Ohm Meter.
- Check wiring the Anti-Ice Panel. Disconnect S7P1, set the rotary switch WING SOURCE to NORM and check that there is no continuity between pin X and pin W, and then between pin X and pin U.