Message Overview:
Message Description:
The outflow valve auto actuator does not receive any data from the IASC-1.
Possible Causes:
- Outflow Valve Auto Actuator (MPE1)
- Integrated Air System Controller (IASC-1) (A55)
- Junction Box 2 (JB2)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Operational Test of the Cabin Pressure Control System | AMM 21-31-00-710-801 |
| Removal of the Outflow Valve | AMM 21-31-05-000-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Check the wiring from the Outflow Valve MPE1 to the IASCs. Dual transmit and receive signals from the IAS Controllers and the outflow enable signal pass through Junction Box #2.
- Perform the Operational Test of the Cabin Pressure Control System and operational test of the outflow valve MPE1, look for operational faults.
- Replace the Outflow Valve.