02/02/21
Message Overview
Message Description:
The outflow valve auto actuator does not receive any data from the IASC-2.
Possible Causes:
- Junction Box 2 (JB2)
- Cabin Pressure Control System Outflow Valve (MPE1)
- Integrated Air System Controller (IASC) (A56)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-21-0047 - No MDC Report upon "AUTO PRESS FAIL" CAS Message (20003 - 20500)
- SB 100-21-10 - Modification - Cabin-Pressure Control System - Software Change of the Integrated Air System Controller (IASC) Part No. 92175A030400 to Part No. 92175A30500 (20003 - 20291)
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Operational Test of the Cabin Pressure Control System | AMM 21-31-00-710-801 |
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Operational Test of the Integrated Air System (IAS) Controller | AMM 21-31-01-710-801 |
| Removal of the Outflow Valve | AMM 21-31-05-000-801 |
| Installation of the Outflow Valve | AMM 21-31-05-400-801 |
| Removal of the Junction Box JB1 | AMM 24-63-05-000-802 |
| Installation of the Junction Box JB1 | AMM 24-63-05-400-802 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Check the wiring from the outflow valve MPE1 to the IASCs. Dual transmit and receive signals from the IAS Controllers and the outflow enable signal pass through Junction Box #2.
- Perform the Operational Test of the Cabin Pressure Control System outflow valve MPE1, look for operational faults.
- Replace the outflow valve.