background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

08/10/21

Message Overview:

Message Name:

NO L-MFD-2 BUS INPUT

Message Code:

B3-289426

Associated CAS:

None

Reporting LRU: IASC1 TST A
System Description: 21-00-00
Schematic Diagram: 21-23-00
Wiring Diagram: 31-61-03

Message Description:

IASC-1 Channel A does not receive any data from the Left MFD.

Possible Causes:

  • Adaptive Flight Display - L Multi-Function Display (L MFD) (A29)
  • Integrated Air System Controller (IASC1) (A55)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Integrated Air System (IAS) Controller AMM 21-31-01-000-801
Installation of the Integrated Air System (IAS) Controller AMM 21-31-01-400-801
Operational Test of the Integrated Air System (IAS) Controller AMM 21-31-01-710-801
Removal of the Adaptive Flight Display Unit AMM 31-61-01-000-801
Installation of the Adaptive Flight Display Unit AMM 31-61-01-400-801
Operational Test of the Electronic Flight Instrument System (EFIS) AMM 31-61-00-710-802
Standard Practices - Replace Wiring SPM 20-12-00-02
Standard Practices - Repair Wiring SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Check the left MFD circuit breaker CB1 C5, reset and re-check MDC for the bus fault.
  2. Check 429 LS data bus (L-MFD-2) A29P1 Pins 77 Hi, 79 Lo, to IASC #1 A55P2 Pin 35 Hi, 8 Lo.
  3. Suspect the MFD for being faulty, interchange or remove and replace.
  4. Operational Test.
  5. Suspect the #1 IAS controller, remove and replace.
  6. Operational Test.
  7. System Schematic 21-23 Pg 3 for IASC data bus wiring.

51_eicas_dcu_rh60_lh_cbpnl