Message Overview:
Message Description:
IASC-1 has detected a disagree between IASC1 and IASC2.
Possible Causes:
- Integrated Air System Controller 1 (IASC1) (A55)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Operational Test of the Integrated Air System (IAS) Controller | AMM 21-31-01-710-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Using Raw data IASC1A, IASC1B, IASC2A, IASC2B, check wiring of discrete input (Emer Depress, Man Press, Ditching, Air Source, WAI on and WAI source) and wiring of analog input (CPCS Cabin Pressure).
- Deferred maintenance, maintenance action can be postponed for convenience.
- Suspect the #1 IAS controller, remove and replace per AMM.
- Operational test IAW AMM.