background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/10/21

Message Overview:


Message Name:

INSTALLED

Message Code:

B3-006938

Associated CAS:

None

Reporting LRU: IOC 1
System Description: 22-00-00
Schematic Diagram: None
Wiring Diagram: None

Message Description:

Prerequisite - Blocks failures caused by a power supply fault.

Possible Causes:

  • Power Supply
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Fault Confirmation Procedure:

  1. Message# = 1
  2. Comp Id = A004
  3. Fault Logged = AIR
  4. Status = DON'T FAIL
  5. {Term Definitions}

    1. FGC1-1 1X 071 01 ABSN XXXX-XXXX XXXX-XXXX XXXX-XXXX 071: (A) NO IOC 1X IN;
    2. IOC2-10 2X 350 10 EXCT XXXT-XXXX XXXX-XXXX XXXX-XXXX 350: 29; PWR SUP 1 O/H

Quick Links:

Standard Practices - Wire Replace SPM 20-12-00-02
Standard Practices - Wire Repair SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Prerequisite - Blocks failures caused by a power supply fault.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.