02/16/21
Message Overview:
Message Name:
NO R-GP-1 BUS OUTPUT
Message Code:
B3-006967
Associated CAS:
| Reporting LRU: | IOC 2 |
| System Description: | 22-00-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
R-GP-1 data not received at 2 of (R-ADC, R-RIU, R-CDU, L-CDU).
Possible Causes:
- Input/Output Concentrator (IOC) 2 (A4-IOC) R-GP-1 Bus Output
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 11
- Fault Logged = AIR, TAXI
- Status = FAILED/WIRING
- Message Type = Fault Message
- {Term Definitions}
- ADC2-4 2X 350 10 EXCT XXXX-XXXX XXXX-XXXX XTXX-XXXX 350: 15; NO R-GP-1 IN
- RIU2-26 2X 351 10 EXCT XXXX-XXXX XXXX-TXXX XXXX-XXXX 351: 20; R-GPBUS INACTIVE
- CDU2-4 2X 350 10 EXCT XXXX-XXXX XXXX-XXXX XXXT-XXXX 350: 13; NO R-GP-1 BUS INPUT
- CDU1-4 1X 350 01 EXCT XXXX-XXXX XXXX-XXXX XXXT-XXXX 350: 13; NO R-GP-1 IN
Quick Links:
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- R-GP-1 data not received at 2 of (R-ADC, R-RIU, R-CDU, L-CDU). Suspect failed R-GP-1 output or wiring.