background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/23/21

Message Overview:

Message Name:

INSTALLED

Message Code:

B3-008079

Associated CAS:

None

Reporting LRU: VHF 2
System Description: 23-11-00
Schematic Diagram: None
Wiring Diagram: None

Message Description:

No VHF2 installed in the aircraft.

Possible Causes:

  • Very High Frequency Radio (VHF2) (A8)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Fault Confirmation Procedure:

  1. Message# = 0
  2. Fault Logged = AIR
  3. Status = PREREQUISITE
  4. Message Type = Fault Message
  5. {Term Definitions}

    1. OPT1-18 XX 360 NA EXCT CSU WD-03 XXXX-XXXX TXXX-XXXX 16: VHF 2 STRAP

Quick Links:

Removal of the VHF Communication Unit AMM 23-11-01-000-801
Installation of the VHF Communication Unit AMM 23-11-01-400-801
Replacement of DC Circuit Breakers AMM 24-65-00-960-801
Removal of the Cockpit Circuit Breaker Panel (CCBP) AMM 24-65-01-000-801
Installation of the Cockpit Circuit Breaker Panel (CCBP) AMM 24-65-01-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. No VHF2 installed in the aircraft.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.