02/24/21
Message Overview:
Message Name:
NO 429 OUTPUT BUS TO IOC
Message Code:
B3-339590
Associated CAS:
| Reporting LRU: | RIU 1 DATALINK |
| System Description: | 23-22-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
Internal Datalink failure.
Possible Causes:
- Internal Datalink Failure
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 3
- Comp Id = A017
- Fault Logged = AIR, TAXI
- Status = FAILED/WIRING
- {Term Definitions}
- DLNK-2 XX 350 01 EXCT XXXX-XXXX XXXX-XXXX XXXX-XTXX 350: 11; UNILINK FAIL
Quick Links:
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- None