03/01/21
Message Overview:
Message Description:
PSEU detects an unreasonableness (related to rigging) condition seen by the sensor PX44, Right Inboard Ground Spoiler Stowed; target condition (NEAR or FAR) is opposite of what it should be. Sensor is healthy but requires verification and rigging.
Possible Causes:
- Proximity Sensor (RH) (PX44)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Spoiler Proximity Sensor | AMM 27-61-09-000-801 |
| Installation of the Spoiler Proximity Sensor | AMM 27-61-09-400-801 |
| Operational Test of the Ground Spoiler Proximity Sensors | AMM 27-61-09-710-801 |
| Adjustment of the Ground Spoiler Proximity Sensors | AMM 27-61-09-820-802 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Do the rigging with the adjustment of the sensor PX44.
- If system checks are good, do close out.
- If fault remains continue with next step.
- Replace PX44.
- If system checks are good, do close out.
- If fault remains continue with next step.
- Reset the PSEU circuit breakers CB1-C13, CB1-C14, CB2-C13, CB2-C14.
- Do close out.