03/02/21
Message Overview:
Message Description:
Spoiler Rigging failed.
Possible Causes:
- Spoiler Electronic-Control Unit 1 (SECU 1) (A118)
- Variable Differential Transformer (RVDT)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 34
- Comp Id = A118
- {Term Definitions}
- SECU1-47 XX 354 01 EXCT XXXX-XXXX XXXX-XXXX XXXT-XXXX 354 :13; SPOILER RIGGING FAILED
Quick Links:
| Removal of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-000-801 |
| Installation of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-400-801 |
| Electronic Rigging of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-820-801 |
| Electronic Rigging of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-820-802 |
| Removal of the Multi-Function Spoiler Rotary Variable-Differential Transformer (MFS RVDT) | AMM 27-61-11-000-801 |
| Installation of the Multi-Function Spoiler Rotary Variable-Differential Transformer (MFS RVDT) | AMM 27-61-11-400-801 |
| Rigging Check of the Multi-Function Spoiler Rotary Variable-Differential Transformer (MFS RVDT) | AMM 27-61-11-220-801 |
| Operational Test of the Multi-Function Spoiler System | AMM 27-62-00-710-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Verify L-SECU INPUT, XVDT, wiring, Hydraulic or Surface Position.