Message Overview:
Message Description:
PSEU detects a marginal or out of rig condition to the proximity sensor PX04 Right Main Landing Gear Uplock.
Possible Causes:
- Main Landing-Gear Uplock Proximity-Sensor (RH) 32-61-01 (PX04)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Adjustment of the Proximity Sensors | AMM 32-61-00-820-801 |
| Removal of the Main Landing-Gear (MLG) Proximity-Sensors | AMM 32-61-01-000-801 |
| Installation of the Main Landing-Gear (MLG) Proximity-Sensors | AMM 32-61-01-400-801 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
Troubleshooting Recommendations:
- Do the rigging with the adjustment of the sensor PX04.
- If system checks are good, do close out.
- If fault remains continue with next step.
- Replace PX04.
- If system checks are good, do close out.
- If fault remains continue with next step.
- Reset the PSEU circuit breakers CB1-C13, CB1-C14, CB2-C13, CB2-C14.
- Do close out.