Message Overview:
Message Description:
PSEU detects a marginal or out of rig condition to the proximity sensor PX06 Nose Gear Uplock.
Possible Causes:
- Nose Landing-Gear Uplock Proximity-Sensor (PX06)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Adjustment of the Proximity Sensors | AMM 32-61-00-820-801 |
| Removal of the Nose Landing-Gear (NLG) Proximity-Sensors | AMM 32-61-05-000-801 |
| Installation of the Nose Landing-Gear (NLG) Proximity Sensors | AMM 32-61-05-400-801 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do the rigging with the adjustment of the sensor PX06.
- If system checks are good, do close out.
- If fault remains continue with next step.
- Replace PX06.
- If system checks are good, do close out.
- If fault remains continue with next step.
- Reset the PSEU circuit breakers CB1-C13, CB1-C14, CB2-C13, CB2-C14.
- Do close out.