03/11/21
Message Overview:
Message Description:
PSEU detects a marginal or out-of-rig condition to the proximity sensor PX31 Right Main Landing Gear WOW2. Sensor is healthy but requires proper rigging.
Possible Causes:
- Main Landing-Gear Weight-On-Wheels 2 Proximity-Sensor (RH) (PX31)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Adjustment of the Proximity Sensors | AMM 32-61-00-820-801 |
| Removal of the Main Landing-Gear (MLG) Proximity-Sensors | AMM 32-61-01-000-801 |
| Installation of the Main Landing-Gear (MLG) Proximity-Sensors | AMM 32-61-01-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |