03/15/21
Message Overview:
Message Description:
PSEU detects a marginal or out of rig condition to the proximity sensor PX39 Left Main Landing Gear Downlock 2.
Possible Causes:
- Left Main Landing-Gear Downlock 2 Proximity-Sensor (LH) (PX39)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Adjustment of the Proximity Sensors | AMM 32-61-00-820-801 |
| Removal of the Nose Landing-Gear (NLG) Proximity-Sensors | AMM 32-61-05-000-801 |
| Installation of the Nose Landing-Gear (NLG) Proximity Sensors | AMM 32-61-05-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
Troubleshooting Recommendations:
- Do the rigging with the adjustment of the sensor PX39.
- If system checks are good, do close out.
- If fault remains continue with next step.
- Replace PX39.
- If system checks are good, do close out.
- If fault remains continue with next step.
- Reset the PSEU circuit breakers (CB1-C13, CB1-C14,CB2-C13, CB2-C14).
- Do close out.