03/16/21
Message Overview:
Message Description:
PSEU detects an overload condition on the discrete output DOT10A. This is an unused Discrete Output on aircraft with Proline 21 Advanced Upgrade.
Possible Causes:
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
NOTE: This Discrete Output is not used on aircraft with Proline 21 Advanced Upgrade, therefore, PSEU and gear System functionalities won't be affected if this message is the only fault present on the MDC.
- Reset PSEU / gear system circuit breakers CB1-C13, CB1-C14, CB2-C13 and CB2-C14. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Remove PSEU (A9) and inspect the Connectors and Tray for any defect.
- If inspection is satisfactory, continue with next step.
- If inspection is not satisfactory, repair defect.
- Replace PSEU (A9).
- Do close out.