03/19/21
Message Overview:
Message Name:
NO OUTPUT
Message Code:
B3-006477
Associated CAS:
| Reporting LRU: | DCP 1 |
| System Description: | 34-00-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
No L-DCP data received at L-PFD and L-MFD.
Possible Causes:
- Display Control Panel (DCP) (PL7)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- LRU = DCP1 DCP 1
- ATA Chapter = 34-25
- Message# = 1
- Comp Id = PL07
- {Term Definitions}
- MFD1-4 1X 350 NA EXCT XXXX-XXXX XXXX-XXXX XXTX-XXXX 350: 14;NO L-DCP-2 INPUT
- PFD1-5 1X 350 NA EXCT XXXX-XXXX XXXX-XXXX XXTX-XXXX 350: 14;NO L-DCP-1 INPUT
Quick Links:
| Removal of the Control Display Unit (CDU) | AMM 34-61-05-000-801 |
| Installation of the Control Display Unit (CDU) | AMM 34-61-05-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Suspect failed L-DCP output or wiring.