Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

03/22/21

Message Overview:

Message Name:

NO L-CDU-7 BUS INPUT

Message Code:

B3-006573

Associated CAS:

None

Reporting LRU: DME 2
System Description: 34-53-00
Schematic Diagram: 34-53-00
Wiring Diagram: 34-53-01

Message Description:

L-CDU-7 input is absent at R-DME and NOT absent at 3-of (R-NAV, R-TDR, R-VHF, R-HF); only 1 FMC, 1 CDU option strapped.

Possible Causes:

  • Distance Measuring Equipment (DME) Transceiver 2 (RH) (A50)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Fault Confirmation Procedure:

  1. LRU = DME2 DME 2
  2. ATA Chapter = 34-53
  3. Message# = 7
  4. Comp Id = A050
  5. {Term Definitions}

    1. OPT1-31 XX 360 NA EXCT CSU WD-04 XXXX-XXXX XXXX-XFFT 9,10,11: 1 FMC/1 CDU STR
    2. DME2-5 2X 057 10 EXCT XXXX-XXXX XXXX-XXXX XTXX-XXXX 057: 15;NO R-CDU-6/L-CDU-7 IN
    3. VHF2-3 2X 057 10 EXCT XXXX-XXXX XXXX-XXXX XTXX-XXXX 057: 15;NO R-CDU-6/L-CDU-7 INPUT
    4. NAV2-4 2X 057 10 EXCT XXXX-XXXX XXXX-XXXX XTXX-XXXX 057A: 15;NO R-CDU-6/L-CDU-7 IN
    5. HF2-1 2X 351 10 EXCT XXXX-XXXX XXXX-XXXX XXXX-XTXX 351: 11;NO R-CDU-6/L-CDU-7 INPUT
    6. TDR2-4 2X 350 10 EXCT XXXX-XXXX XXXX-XXXX TXXX-XXXX 350: 16;NO R-CDU-6/L-CDU-7 BUS IN

Quick Links:

Removal of the Distance Measuring Equipment (DME) Transceiver AMM 34-53-01-000-801
Installation of the Distance Measuring Equipment (DME) Transceiver AMM 34-53-01-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. Suspect failed R-DME input or wiring.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.