03/22/21
Message Overview:
Message Description:
L-CDU-7 input is absent at R-DME and NOT absent at 3-of (R-NAV, R-TDR, R-VHF, R-HF); only 1 FMC, 1 CDU option strapped.
Possible Causes:
- Distance Measuring Equipment (DME) Transceiver 2 (RH) (A50)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- LRU = DME2 DME 2
- ATA Chapter = 34-53
- Message# = 7
- Comp Id = A050
- {Term Definitions}
- OPT1-31 XX 360 NA EXCT CSU WD-04 XXXX-XXXX XXXX-XFFT 9,10,11: 1 FMC/1 CDU STR
- DME2-5 2X 057 10 EXCT XXXX-XXXX XXXX-XXXX XTXX-XXXX 057: 15;NO R-CDU-6/L-CDU-7 IN
- VHF2-3 2X 057 10 EXCT XXXX-XXXX XXXX-XXXX XTXX-XXXX 057: 15;NO R-CDU-6/L-CDU-7 INPUT
- NAV2-4 2X 057 10 EXCT XXXX-XXXX XXXX-XXXX XTXX-XXXX 057A: 15;NO R-CDU-6/L-CDU-7 IN
- HF2-1 2X 351 10 EXCT XXXX-XXXX XXXX-XXXX XXXX-XTXX 351: 11;NO R-CDU-6/L-CDU-7 INPUT
- TDR2-4 2X 350 10 EXCT XXXX-XXXX XXXX-XXXX TXXX-XXXX 350: 16;NO R-CDU-6/L-CDU-7 BUS IN
Quick Links:
| Removal of the Distance Measuring Equipment (DME) Transceiver | AMM 34-53-01-000-801 |
| Installation of the Distance Measuring Equipment (DME) Transceiver | AMM 34-53-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Suspect failed R-DME input or wiring.