04/02/21
Message Overview:
Message Name:
NO OUTPUT
Message Code:
B3-648448
Associated CAS:
| Reporting LRU: | AHC 1 |
| System Description: | None |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
No L-AHC data received at the L-IOC and 3-of (L-FGC, L-PFD, L-MFD, R-PFD, R-MFD).
Possible Causes:
- Attitude Heading Computer 1 (AHC) (A11)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 2
- {Term Definitions}
- AHC1-1 1X 350 01 ABSN XXXX-XXXX XXXX-XXXX XXXX-XXXX 350:(A) NO IOC 1X IN;
- OPT1-91 XX 360 NA EXCT CSU WD-06 TTTX-XXXX XXXX-XXXX CSU_06:16&15&14; TSS
- FGC1-5 1X 071 01 EXCT XXXX-XXXT XXXX-XXXX XXXX-XXXX 071:25;NO L-AHRS-1 BUS INPUT
- TTRA-7 1X 350 00 EXCT XXXX-XXXX XXXX-XTXX XXXX-XXXX 350:19;L-AHC-1 BUS INPUT
- PFD1-24 1X 351 NA EXCT XXXX-XXXX XXXX-XXXX XXTX-XXXX 351:14;NO L-IRS\AHC-2 INPUT
- MFD1-22 1X 351 NA EXCT XXXX-XXXX XXXX-XXXX XXTX-XXXX 351:14;NO L-IRS\AHC-2 INPUT
- PFD2-23 2X 351 NA EXCT XXXX-XXXX XXXX-XXXX XXTX-XXXX 351:14;NO L-IRS\AHC-3 INPUT
- MFD2-24 2X 351 NA EXCT XXXX-XXXX XXXX-XXXX XXTX-XXXX 351:14;NO L-IRS\AHC-3 INPUT
Quick Links:
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- L-AHC requires replacement or troubleshooting.