Message Overview:
Message Description:
The HIGH PRESS VALVE 1 is detected failed in open position.
Possible Causes:
- High Pressure Valve 1 (HPV) (V5)
- Position Switch
- Integrated Air System Controller 1 (IASC) (A55)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 2
- {Term Definitions}
- IAS1A-69 XX 353 01 EXCT XXXX-XXXX XXXX-XTXX XXXX-XXXX 353B: 19; HI PRESS VALVE 1 FAIL
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Leak Test of the High-Pressure Bleed-Air System | AMM 36-15-00-790-801 |
| Removal of the High Pressure Valve | AMM 36-15-01-000-801 |
| Installation of the High Pressure Valve | AMM 36-15-01-400-801 |
| Removal of the High Pressure Sensors | AMM 36-15-03-000-801 |
| Installation of the High Pressure Sensors | AMM 36-15-03-400-801 |
| Operational Test of the Maintenance Diagnostic System | AMM 45-45-00-710-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Check valve or position switch or wiring between the valve, and the IASC #1.