04/07/21
Message Overview:
Message Description:
RB-IOC-5 data absent at Maintenance Diagnostic Computer (MDC).
Possible Causes:
- Maintenance Diagnostic Computer (MDC) (A4-MDC)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Maintenance Diagnostic Computer (MDC) | AMM 45-45-01-000-801 |
| Installation of the Maintenance Diagnostic Computer (MDC) | AMM 45-45-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset R IAPS Circuit Breaker CB2-B6. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Re-rack MDC. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace MDC. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace IAPS Card Cage (A4).
- Do close out.