04/08/21
Message Overview:
Message Description:
File Server Unit (FSU) 1 has reported a communication fault between the Multi-Function Display (MFD) and the Maps application within the File Server Unit (FSU) Software Application (FSA). Reset power to the FSU 1.
Possible Causes:
- Multi-Function Display 1 (MFD 1) (A29)
- Multi-Function Display 2 (MFD 2) (A28)
- File Server Unit (FSU) Software Application (FSA) (FSA-5000)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Operational Test of the Single Integrated Flight Information System (IFIS) | AMM 46-21-00-710-801 |
| Operational Test of the Dual Integrated Flight Information System (IFIS) | AMM 46-21-00-710-803 |
| Load the FSA-5000 Application Software to the File Server Unit (FSU) | AMM 46-21-01-970-801 |
| Removal of the File Server Unit (FSU) | AMM 46-21-01-000-801 |
| Installation of the File Server Unit (FSU) | AMM 46-21-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- On Reversionary Switch Panel (RSP), set the LEFT DISPLAYS or RIGHT DISPLAYS switch to PFD REV and then back to NORM.
- If it does not recover, reset FSU 1 circuit breaker CB1-C6 (L FILE SERVER).