04/08/21
Message Overview:
Message Description:
File Server Unit (FSU) 2 software detected a software fault. This would include faults relating to a mis-configuration of the File Server Unit (FSU) Software Application (FSA) software. Reload FSU Software Application (FSA-5000).
Possible Causes:
- File Server Unit (FSU) Software Application (FSA-5000)
- Right File Server Unit 2 (FSU 2) (A222)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
References:
- Encrypted Application Key Enabling, refer to the IFIS Installation manual (Rockwell Collins CPN 523-0780854) for installation specifics.
- Subscription Database Installation, refer to the Field Loadable Software installation Manual (Rockwell Collins CPN 523-0806267).
- Rockwell Collins SIL 1-03 for the procedures of FSU software loading and subscription database installation.
- Pro Line 21 Continuum IFIS-5000 Installation Manual (Rockwell Collins CPN 523-0780854).
- Field Loadable Software Installation Manual (Rockwell Collins CPN 523-0806267).
- CPAS-3000 Data Loader Operator's Guide (Rockwell Collins CPN 523-0790386).
Quick Links:
| Operational Test of the Single Integrated Flight Information System (IFIS) |
AMM 46-21-00-710-801 |
| Operational Test of the Dual Integrated Flight Information System (IFIS) |
AMM 46-21-00-710-803 |
| Removal of the File Server Unit (FSU) | AMM 46-21-01-000-801 |
| Installation of the File Server Unit (FSU) | AMM 46-21-01-400-801 |
| Load the FSA-5000 Application Software to the File Server Unit (FSU) |
AMM 46-21-01-970-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-00-02 |
Troubleshooting Recommendations:
The FSA-5000 is software that is loaded on the FSU-5010 and includes three feature options: The display of electronic charts, enhanced map overlays, and graphical weather.
- FSA-5000 FSU Application Software
(CPN 810-0001-002/003/004/005/006/008/009/100/104/105/106/108/109) - The new FSA version, CPN 810-0001-009, improves the operation of the OVL-5000.
The new FSA version, CPN 810-0001-109, improves the operation of the GWX-300X NEXRAD Map Overlay and improves the operation of the OVL-5000.
- Check the part number of the FSA and software version for the FSU 2.
- Refer to tables below for Software Versions. For verification of software loaded on the aircraft, verify that the FSA part number and CRC on the Multi-function Display match those in the compatibility chart.
FSA-5000 INSTALLATION AND BENCH VERIFICATION DATA FSA-5000 COL_NODE TARGET
FSU NODE LOADSETCOL_FSU TARGET
FSU CPR LOADSETCPN CRC CPN CRC 810-0001-002 815-5596-002 8151DCFC 810-0001-002 AFF014F1 810-0001-003 815-5596-002 8151DCFC 810-0001-003 2BB1AE59 810-0001-100 815-5596-101 54E274B2 810-0001-100 10889FD8 810-0001-004 815-5596-002 8151DCFC 810-0001-004 DED14ADF 810-0001-104 815-5596-101 54E274B2 810-0001-104 8CEF1F9A 810-0001-005 815-5596-003 CB8333B7 810-0001-005 73B2184B 810-0001-105 815-5596-101 54E274B2 810-0001-105 765E1E2F 810-0001-006 815-5596-003 CB8333B7 810-0001-006 42DAF90F 810-0001-106 815-5596-102 17966CDC 810-0001-106 0E568A9B 810-0001-008 815-5596-005 2D20F306 810-0001-008 5C9B91DC 810-0001-108 815-5596-104 CCEAFB31 810-0001-108 C0B855B3 810-0001-009 815-5596-006 EA41DDB0 810-0001-009 9AB8A460 810-0001-109 815-5596-105 B5FFE384 810-0001-109 88C85366 FSU-5010 / FSA-5000 COMPATIBILITY FSA-5000 FSU-5010 (CPN 822-1543-XXX) 101 810-0001-002 * 810-0001-003 * 810-0001-100 * 810-0001-004 * 810-0001-104 * 810-0001-005 * 810-0001-105 * 810-0001-006 * 810-0001-106 * 810-0001-008 * 810-0001-108 * 810-0001-009 * 810-0001-109 * FSA-5000 / OVL-5000 COMPATIBILITY OVL-5000 FSA-5000 (CPN 810-0001-XXX) 002 003 100 004 104 005 105 006 106 008 108 009 109 810-0003-001 * * * * * * * * * * * * * FSA-5000 / ECH-5000 COMPATIBILITY ECH-5000 FSA-5000 (CPN 810-0001-XXX) 002 003 100 004 104 005 105 006 106 008 108 009 109 810-0002-001 * * * * * * * * * * * * * FSA-5000 / GWX-5000 COMPATIBILITY GWX-5000 FSA-5000 (CPN 810-0001-XXX) 002 003 100 004 104 005 105 006 106 008 108 009 109 810-0004-001 * * * * * * FSA-5000 / GWX-3000 COMPATIBILITY GWX-3000 FSA-5000 (CPN 810-0001-XXX) 002 003 100 004 104 005 105 006 106 008 108 009 109 810-0007-001 * * * * * * FSA-5000 / GWX-3001 COMPATIBILITY GWX-3001 FSA-5000 (CPN 810-0001-XXX) 002 003 100 004 104 005 105 006 106 008 108 009 109 810-0058-001 * * NOTE: The marking for the FSA-5000 is shown on the CD Rom face. The FSA-5000 part number, build date and cyclical redundancy check number for the CPR load set are also available on the avionics display. See the Field Loadable Software Installation Manual (CPN 523-0806267) for procedure to display the FSA part number information.
- Refer to tables below for Software Versions. For verification of software loaded on the aircraft, verify that the FSA part number and CRC on the Multi-function Display match those in the compatibility chart.
- If the part number or software version is not compatible, install the correct software to FSU 2, refer to the FSU-5010 section of the Field Loadable Software Installation Manual (CPN 523-0806267) for installation instructions.
NOTE:- The FSA-5000 must be installed prior to enabling applications.
- The FSA-5000 must be installed prior to installing the databases.
Refer to the IFIS Installation manual (CPN 523-0780854) for installation specifics.
- If the message can not be cleared after the above actions, swap the FSU 2 with the FSU 1 (A221).
- If step 3 does not help, replace the FSU No. 2.