background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/09/21

Message Overview:

Message Name:

AEBDRCL RIGGING

Message Code:

B3-007537

Associated CAS:

None

Reporting LRU: AEBDRCL SNSR
System Description: 32-60-00
Schematic Diagram: 32-61-00
Wiring Diagram: 32-61-09
32-61-12
52-71-05

Message Description:

Proximity Sensor Electronic Unit (PSEU) detects a marginal or out of rig condition to the Proximity Sensor PX47, Aft Equipment Bay Door Closed. Sensor is healthy, but requires proper rigging.

Possible Causes:

  • AFT EQPT Bay Door Closed Proximity Sensor (PX47)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Functional Test of the Proximity-Sensor Electronic Unit (PSEU) AMM 32-61-09-720-801
Built-In Test of the Door Proximity-Sensors AMM 52-71-00-740-801
Removal of the Aft-Equipment-Compartment Door Proximity-Sensor AMM 52-71-13-000-801
Installation of the Aft-Equipment-Compartment Door Proximity-Sensor AMM 52-71-13-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Do the rigging with the adjustment of the sensor.

    1. If the rigging is good, do close out.
    2. If fault remains, continue with next step.

  2. Replace the sensor.
  3. Reset the PSEU circuit breakers (CB1-C13, CB1-C14, CB2-C13, CB2-C14).
  4. Do close out.

proximity_sensorprox_switch60_lh_cbpnl60_rh_cbpnl

Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.