background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/09/21

Message Overview:

Message Name:

ROEDRLK REASONABLENESS

Message Code:

B3-007544

Associated CAS:

EMERGENCY EXIT
(Caution)

Reporting LRU: ROEDRLK SNSR
System Description: 32-60-00
Schematic Diagram: 32-61-00
Wiring Diagram: 52-71-05

Message Description:

Proximity Sensor Electronic Unit (PSEU) detects an unreasonable (related to rigging) condition to the Proximity Sensor PX49, Right-hand Over-Wing Emergency Door Locked; target condition (NEAR or FAR) is opposite of what it should be. Sensor is healthy but requires proper rigging.

Possible Causes:

  • Proximity Sensor Electronic Unit (PSEU) (A9)
  • Right Overwing Emergency Door Closed Proximity Sensor (PX49)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Proximity-Sensor Electronic Unit (PSEU) AMM 32-61-09-000-801
Installation of the Proximity-Sensor Electronic Unit (PSEU) AMM 32-61-09-400-801
Functional Test of the Proximity-Sensor Electronic Unit (PSEU) AMM 32-61-09-720-801
Operational Test of the Emergency Exit Proximity-Sensor AMM 52-71-00-710-802
Built-In Test of the Door Proximity-Sensors AMM 52-71-00-740-801
Removal of the Over-Wing Emergency-Exit Proximity-Sensor AMM 52-71-21-000-801
Installation of the Over-Wing Emergency-Exit Proximity-Sensor AMM 52-71-21-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Do the mechanical adjustment (rigging) for PX49 (Installation of the Over-Wing Emergency-Exit Proximity Sensor).
  2. Do the Built-In-Test of the Door Proximity Sensors.

    1. If test is good, do close out.
    2. If fault remains, continue with next step.

  3. Replace PX49.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  4. Do close out.

pseu_locationproximity_sensor5