04/26/21
Message Overview:
Message Description:
The red 'ATT' warning flag indicates invalid attitude source.
- A loss of all attitude data from the selected IRS, most likely caused by an IRS fault or power failure. Verification of system failure can be checked on the MDC current fault page for further system details.
Possible Causes:
- Input/Output Concentrator (IOC) (A4-IOC)
- Inertial Reference Unit 1 (IRS 1) (A233)
- Inertial Reference Unit 2 (IRS 2) (A232)
- Data Bus Failure
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Operational Test of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-710-801 |
| Operational Test of the Inertial Reference System (IRS) | AMM 34-45-00-710-801 |
| Removal of the Inertial Reference Unit (IRU) | AMM 34-45-01-000-801 |
| Installation of the Inertial Reference Unit (IRU) | AMM 34-45-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- None