04/27/21
Message Overview:
Message Description:
A delay is observed for the light-off during an engine start. It may be accompanied by an audible boom sound.
Possible Causes:
- Outside Air Temperature (OAT)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
- Honeywell SIL D201204000044 - Delayed Light-off (Booming) Starts on AS907 Engine Models
Quick Links:
| Prepare for Engine Operation | AMM 71-00-00-866-802 |
| Pre-Start Checks | AMM 71-00-00-866-804 |
| Start the Engine | AMM 71-00-00-866-807 |
| Engine Shutdown Check | AMM 71-00-00-866-810 |
| Engine Post-Operation Check | AMM 71-00-00-866-811 |
Troubleshooting Recommendations:
- Please see Honeywell investigation details in Honeywell SIL D201204000044 - Delayed Light-off (Booming) Starts on AS907 Engine Models.
- If condition applies, you may attempt an engine start using continuous ignition, detailed in SIL D201204000044.
- Do close out.