01/25/21
Message Overview:
Message Description:
The amber 'APU FIRE DET FAIL' caution CAS message indicates the APU fire detection system has determined a failure that will not allow the detection system to indicate a fire.
- During normal operation and stand-by modes the FIREX-CU performs a fire/overheat periodic BIT once every five (5) minutes. A periodic BIT consists of the following:
- Test detector loop open circuits.
- Test detector loop fire/overheat detection capability - specifically continuity of each loop's center wire.
- Test detector loop monitoring and short circuit detection circuitry - only if a loop fails the fire test.
- Test fire & overheat warning discrete output drivers.
If one of these steps fail for the APU system, the amber APU FIRE DET FAIL will be displayed.
Possible Causes:
- None
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
- None