Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

01/29/21

Message Overview:

Message Name:

DISAGREE / VALVE CLOSED

Message Code:

B3-006372

Associated CAS:

EQPT RACK TEMP HIGH
(Caution)

EQPT RACK COOL FAULT
(Advisory)

Reporting LRU: AVIONICS VALVE
System Description: 21-61-00
Schematic Diagram: 21-23-00
Wiring Diagram: 21-23-05

Message Description:

The AVIONICS VALVE is detected failed in closed position.

Possible Causes:

  • Avionics Cooling Valve (MPE14)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Fault Confirmation Procedure:

  1. LRU = AVLV AVIONICS VALVE
  2. ATA Chapter = 21-61
  3. Message# = 1
  4. Comp Id = MPE14
  5. Message = DISAGREE / VALVE CLOSED
  6. Fault Logged = AIR,TAXI
  7. Status = FAILED/WIRING
  8. Message Type = Fault Message
  9. CAS/Cockpit = EQPT RACK COOL FAULT (advisory)
  10. Timer = 5
  11. Logic = IAS1A-41 OR IAS2A-102
  12. {Term Definitions}

    • IAS1A-41 XX 352 00 EXCT XXXX-XXXX XXTX-XXXX XXXX-XXXX 352A:22; AVIONICS VLV FAIL / CLO
    • IAS2A-102 XX 352 10 EXCT XXXX-XXXX XXTX-XXXX XXXX-XXXX 352A:22;AVIONICS VLV FAIL/CLOSED

  13. Equ Note = None
  14. MCID = None
  15. LMMT = None
  16. Equ Descr = The AVIONICS VALVE is detected failed in closed position. Check the valve or the valve position switch or the wiring to the valve.

Quick Links:

Removal of the Avionics Cooling Valve AMM 21-23-09-000-801
Installation of the Avionics Cooling Valve AMM 21-23-09-400-801
Deactivation of the Avionics Cooling Valve (for Maintenance) AMM 21-23-09-040-801
Activation of the Avionics Cooling Valve (for Maintenance) AMM 21-23-09-440-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. Check the valve or the valve position switch or the wiring to the valve.