01/29/21
Message Overview:
Message Description:
The channel A of the RIGHT EQUIPMENT RACK VENTILATED TEMPERATURE SENSOR is detected failed.
Possible Causes:
- Ventilated Temperature Sensor (MT30)
- Integrated Air System Controller 1 (IASC 1) (A55)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 2
- Fault Logged = AIR,TAXI
- Status = FAILED/WIRING
- Timer = 7
- Logic = IAS1A-49
- {Term Definitions}
- IAS1A-49 XX 353 00 EXCT XXXX-XXXX XXXX-XXXX XXXT-XXXX 353A:13; R EQPT RACK VENT SNSR A
Quick Links:
| Removal of the Equipment Rack Vent Temperature Sensor | AMM 21-23-01-000-801 |
| Installation of the Equipment Rack Vent Temperature Sensor | AMM 21-23-01-400-801 |
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Check the sensor or the wiring to the sensor and the IASC #1.