background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/02/21

Message Overview:

Message Name:

DISCRETE INPUT TO DCU
(Service Message)

Message Code:

B3-006704

Associated CAS:

None

Reporting LRU: FLOW CTRL VLV1
System Description: 21-61-00
Schematic Diagram: None
Wiring Diagram: None

Message Description:

The LEFT FLOW CONTROL VALVE has been detected open while air source is Pack Only or Air Source Off.

Possible Causes:

  • Left Flow Control Valve (MPE03)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Fault Confirmation Procedure:

  1. Message# = 5
  2. Fault Logged = AIR,TAXI
  3. Status = FAILED/WIRING
  4. Message Type = Service Message
  5. {Term Definitions}

    1. DWDC2-4 2X 106 00 EXCT XXXX-XXXX XXXX-XXXX XXTX-XXXX 106B: 14;L FCV OPEN
    2. DWDC2-18 2X 111 00 EXCT XXXX-XXXX XXXX-TXXX XXXX-XXXX 111B: 20;TRIM AIR ONLY SELECTED
    3. DWDC2-17 2X 111 00 EXCT XXXX-XXXX XXXX-XTXX XXXX-XXXX 111B: 19;AIR SOURCE SELECTED OFF

Quick Links:

Installation of Integrated Air System (IAS) Controller AMM 21-31-01-000-801
Removal of Integrated Air System (IAS) Controller AMM 21-31-01-400-801
Operational Test of the Integrated Air System (IAS) Controller AMM 21-31-01-710-801
Removal of Flow Control Valve AMM 21-51-09-000-801
Deactivation of the Flow Control Valve AMM 21-51-09-040-801
Installation of Flow Control Valve AMM 21-51-09-400-801
Activation of the Flow Control Valve AMM 21-51-09-440-801
Standard Practices - Replace Wiring SPM 20-12-00-02
Standard Practices - Repair Wiring SPM 20-12-10-02

Troubleshooting Recommendations:

  1. The LEFT FLOW CONTROL VALVE has been detected open while air source is Pack Only or Air Source Off.
  2. Check wiring.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.