background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/02/21

Message Overview:

Message Name:

AIR SYSTEM CONT 1 FAIL

Message Code:

B3-006895

Associated CAS:

None

Reporting LRU: IASC1 TST A
System Description: 21-23-00
Schematic Diagram: 21-23-00
Wiring Diagram: 21-31-03

Message Description:

The channel A or the channel B of the IASC-1 is inoperative due to an internal failure of the controller.

Possible Causes:

  • Integrated Air System Controller (IASC1) (A55)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Integrated Air System (IAS) Controller AMM 21-31-01-000-801
Installation of the Integrated Air System (IAS) Controller AMM 21-31-01-400-801
Operational Test of the Integrated Air System (IAS) Controller AMM 21-31-01-710-801
Standard Practices - Replace Wiring SPM 20-12-00-02
Standard Practices - Wire Repair SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Check the #1 IAS controller circuit breaker CB1 D14 & CB1 E10, reset and re-check MDC for the bus fault.
  2. Check the #1 Integrated Air System Controller 28 VDC power input from CB1 D14 plug A55P2 pins 1 & 2. Verify the IAS controller channel A grounds A55P2 pins 3 & 4.
  3. Suspect the #1 IAS controller, remove and replace Integrated Air System (IAS) Controller.
  4. Operational test of the Integrated Air System (IAS) Controller.

60_lh_cbpnl10_2iasc_location10_iasc_controller_location