11/10/20
Message Overview:
Message Description:
The channel A or the channel B of the IASC-2 is inoperative due to an internal failure of the controller.
Possible Causes:
- Integrated Air System Controller (IASC2) (A56)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Operational Test of the Integrated Air System (IAS) Controller | AMM 21-31-01-710-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Check the #2 IAS controller circuit breaker CB2 D14 & CB2 E10, reset and re-check MDC for the bus fault.
- Check #2 IAS controller power and grounds.
- Suspect the #2 IAS controller, remove and replace Integrated Air System (IAS) Controller.
- Operational test of the Integrated Air System (IAS) Controller.