02/02/21
Message Overview:
Message Name:
IASC2 RS422 DISABLE FAIL
Message Code:
B3-006921
Associated CAS:
| Reporting LRU: | IASC2 TST A |
| System Description: | 21-61-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
The discrete input AUTO PRESS 1 IN from the IASC-1 to the IASC-2 is detected failed.
Possible Causes:
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 12
- Fault Logged = AIR,TAXI
- Status = FAILED/WIRING
- Message Type = Fault Message
- {Term Definitions}
- IAS2A-4 XX 350 10 EXCT XXXX-XXXX XXXX-XXTX XXXX-XXXX 350A: 18; IASC-2 RS422 DISABLE CM
Quick Links:
| Operational Test of the Cabin Pressure Control System | AMM 21-31-00-710-801 |
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Operational Test of the Integrated Air System (IAS) Controller | AMM 21-31-01-710-801 |
| Removal of the Outflow Valve | AMM 21-31-05-000-801 |
| Installation of the Outflow Valve | AMM 21-31-05-400-801 |
| Removal of the Junction Box JB2 | AMM 24-63-05-000-803 |
| Installation of the Junction Box JB2 | AMM 24-63-05-400-803 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- The discrete input AUTO PRESS 1 IN from the IASC-1 to the IASC-2 is detected failed.
- Check wiring.