08/09/21
Message Overview:
Message Description:
Both A & B channels of the IASC-2 do not receive any data from the Data Concentrator Unit channel A.
Possible Causes:
- Integrated Air System Controller (IASC2) (A56)
- Data Concentrator Unit (DCU) (A14)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 14
- Fault Logged = AIR,TAXI
- Status = LRU OK / INFO
- Message Type = Fault Message
- {Term Definitions}
- IAS2A-89 XX 354 10 EXCT XXXX-XXXX XXXX-XXXX TXXX-XXXX 354A: 16; NO A-DCU-4 BUS INPUT
- IAS2A-97 XX 354 11 EXCT XXXX-XXXX XXXX-XXXX TXXX-XXXX 354B: 16; NO A-DCU-4 BUS INPUT
- DCU1-1 1X 340 01 ABSN XXXX-XXXX XXXX-XXXX XXXX-XXXX 340: (A) NO IOC 1X IN
- IAS1A-84 XX 354 00 EXCT XXXX-XXXX XXXX-XXXX TXXX-XXXX 354A: 16; NO DCU-4 CHANNEL A BUS
- IAS1A-92 XX 354 01 EXCT XXXX-XXXX XXXX-XXXX TXXX-XXXX 354B: 16; NO DCU-4 CHANNEL A BUS
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Operational Test of the Integrated Air System (IAS) Controller | AMM 21-31-01-710-801 |
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Both A & B channels of the IASC-2 do not receive any data from the Data Concentrator Unit channel A. Suspect DCU.