08/09/21
Message Overview:
Message Description:
The automatic actuator of the OUTFLOW VALVE is detected failed.
Possible Causes:
- Cabin Pressure Control System Outflow Valve (MPE1)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-21-0047 - No MDC Report upon "AUTO PRESS FAIL" CAS Message (20003 - 20500)
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Operational Test of the Cabin Pressure Control System | AMM 21-31-00-710-801 |
| Removal of the Outflow Valve | AMM 21-31-05-000-801 |
| Installation of the Outflow Valve | AMM 21-31-05-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset Outflow Valve circuit breakers CB3-D6 and CB4-D6.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Outflow Valve.
- Do close out.