01/20/25
Message Overview:
Message Description:
The emergency RAM AIR VALVE is detected failed closed by the Data Concentrator Unit or the discrete wiring to the Data Concentrator Unit is failed.
Possible Causes:
- Data Concentrator Unit (DCU) (A14)
- Ram Air Valve (RAV) (MPE40)
- Position Switch
- Bleed/Air Conditioning Panel (PL17)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
Fault Confirmation Procedure:
- Message# = 4
- Fault Logged = AIR,TAXI
- Status = FAILED/WIRING
- Message Type = Fault Message
- {Term Definitions}
- DWDC2-19 2X 111 00 EXCT XXXX-XXXX XXXT-XXXX XXXX-XXXX 111B: 21;RAM AIR SELECTED ON
- DWDC2-15 2X 110 00 EXCT XXXX-XXXT XXXX-XXXX XXXX-XXXX 110R: 25;RAV OPEN
Quick Links:
| Standard Aircraft Configuration for Maintenance | AMM 12-00-00-867-803 |
| Removal of the Ram-Air Regulating-Valve | AMM 21-53-05-000-801 |
| Installation of the Ram-Air Regulating-Valve | AMM 21-53-05-400-801 |
| Deactivation of the Ram-Air Regulating Valve | AMM 21-53-05-040-801 |
| Activation of the Ram-Air Regulating Valve | AMM 21-53-05-440-801 |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 |
| Electrostatic-Discharge Safety Precautions | AMM 24-00-00-910-802 |
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 |
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Removal of the Bleed-Air Control Panel | AMM 36-11-57-000-801 |
| Installation of the Bleed-Air Control Panel | AMM 36-11-57-400-801 |
Troubleshooting Recommendations:
- Logic: NOT RAV_OPEN AND Ram_Air_Selected_ON.
- The emergency RAM AIR VALVE is detected failed closed by the Data Concentrator Unit or the discrete wiring to the Data Concentrator Unit is failed.
- Check valve or position switch or wiring between the valve and the bleed/air conditioning panel.