Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

08/10/21

Message Overview:

Message Name:

R EQPT RACK OVERHEAT

Message Code:

B3-007770

Associated CAS:

EQPT RACK TEMP HIGH
(Caution)

Reporting LRU: R RACK OVERHEAT
System Description: 21-61-00
Schematic Diagram: None
Wiring Diagram: None

Message Description:

The right equipment rack ambient temperature has been detected above the maximum allowed limit considering the avionics cooling system status.

Possible Causes:

  • Right Equipment Rack Low Pressure Duct
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Fault Confirmation Procedure:

  1. Message# = 1
  2. Fault Logged = AIR,TAXI,GND
  3. Status = OVERHEAT
  4. Message Type = Fault Message
  5. {Term Definitions}

    1. IAS2A-67 XX 353 10 EXCT XXXX-TXXX XXXX-XXXX XXXX-XXXX 353A: 28; R EQUIPMENT RACH OVERHEAT
    2. IAS1A-62 XX 353 00 EXCT XXXX-TXXX XXXX-XXXX XXXX-XXXX 353A: 28; R EQUIPMENT RACK OVERHEAT

Quick Links:

Removal of the Rack Outlet Flexible-Hose AMM 21-23-21-000-801
Installation of the Rack Outlet Flexible-Hose AMM 21-23-21-400-801
Standard Practices - Replace Wiring SPM 20-12-00-02
Standard Practices - Repair Wiring SPM 20-12-10-02

Troubleshooting Recommendations:

  1. The right equipment rack ambient temperature has been detected above the maximum allowed limit considering the avionics cooling system status.
  2. Check the low pressure duct of the right equipment rack.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.