08/09/21
Message Overview:
Message Name:
CSU STRAP - A/C TYPE ERROR
Message Code:
B3-006471
Associated CAS:
| Reporting LRU: | CSU 1 |
| System Description: | 31-45-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
IOC reports Configuration Strapping Unit 1 does not match the aircraft type.
Possible Causes:
- Configuration Strapping Unit 1 (CSU) (A4-CSU)
- Input/Output Concentrator Unit (IOC) (A4-IOC)
- Integrated Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
| Configuration Strapping - BD-100 (LABEL 360 - word 8 aircraft type) |
||||||||
|---|---|---|---|---|---|---|---|---|
| Aircraft Type code I | Aircraft Type code II | |||||||
| Bit # | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
| Setting | 1 | 0 | 1 | 1 | 0 | 0 | 1 | 1 |
- Switch UP or Strap present = Logic 0.
- Switch Down or Strap broken out = Logic 1.
Strapping for CSU 1 & 2 can be compared by simultaneously looking at CSU DATA (LEFT) and CSU DATA (RIGHT) on the MDC CONFIGURATION DATA page.
Quick Links:
| Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Removal of the Configuration Strapping Unit (CSU) | AMM 31-45-17-000-801 |
| Configuration Setting of the Configuration Strapping Unit (CSU) | AMM 31-45-17-280-801 |
| Installation of the Configuration Strapping Unit (CSU) | AMM 31-45-17-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do the Configuration Setting of the Configuration Strapping Unit. Re-configure as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Interchange CSUs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Interchange IOCs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace IAPS Card Cage.
- Do close out.