background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/03/21

Message Overview:

Message Name:

CSU STRAP-A/C TYPE ERROR

Message Code:

B3-006474

Associated CAS:

None

Reporting LRU: CSU 2
System Description: 31-45-00
Schematic Diagram: None
Wiring Diagram: None

Message Description:

IOC reports Configuration Strapping Unit 2 does not match the aircraft type.

Possible Causes:

  • Configuration Strapping Unit 2 (CSU) (A4-CSU)
  • Input/Output Concentrator Unit (IOC) (A4-IOC)
  • Integrated Avionics Processor System (IAPS) Card Cage (ICC) (A4)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Configuration Strapping - BD-100
(LABEL 360 - word 8 aircraft type)
Aircraft Type code I Aircraft Type code II
Bit # 8 7 6 5 4 3 2 1
Setting 1 0 1 1 0 0 1 1

  • Switch UP or Strap present = Logic 0.
  • Switch Down or Strap broken out = Logic 1.

Strapping for CSU 1 & 2 can be compared by simultaneously looking at CSU DATA (LEFT) and CSU DATA (RIGHT) on the MDC CONFIGURATION DATA page.

Quick Links:

Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) AMM 31-45-01-000-801
Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) AMM 31-45-01-400-801
Removal of the Input/Output Concentrator Unit (IOC) AMM 31-45-05-000-801
Installation of the Input/Output Concentrator Unit (IOC) AMM 31-45-05-400-801
Removal of the Configuration Strapping Unit (CSU) AMM 31-45-17-000-801
Configuration Setting of the Configuration Strapping Unit (CSU) AMM 31-45-17-280-801
Installation of the Configuration Strapping Unit (CSU) AMM 31-45-17-400-801

Troubleshooting Recommendations:

  1. Do the Configuration Setting of the Configuration Strapping Unit. Re-configure as required.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. Swap CSUs.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  3. Swap IOCs.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  4. Replace IAPS Card Cage.
  5. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.