02/03/21
Message Overview:
Message Description:
R-FGC xtalk data absent at L-FGC.
Possible Causes:
- Right Flight Guidance Computer (FGC) 2 (A4-FGC)
- Left Flight Guidance Computer (FGC) 1 (A4-FGC)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of Flight Guidance Computer (FGC) | AMM 22-11-01-000-801 |
| Installation of Flight Guidance Computer (FGC) | AMM 22-11-01-400-801 |
| Removal of Integrated Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of Integrated Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset L IAPS Circuit Breaker CB1-B6 and R IAPS Circuit Breaker CB2-B6. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
NOTE: Before you open the IAPS circuit breakers, make sure that all Engine FADEC circuit breakers are open. If the Engine FADEC circuit breakers remain closed, Engine Igniters will activate. This can cause injury to persons and damage to equipment.
- Replace right FGC. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace left FGC. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Check wiring.
- Replace IAPS card cage (A4).
- Do close out.