02/10/21
Message Overview:
Message Description:
L IOC is indicating that more input labels are coming into the IOC than the IOC can output.
Possible Causes:
- Left Input/Output Concentrator Unit (IOC) 1 (A4-IOC)
- Associated Line Replaceable Unit (LRU)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
Troubleshooting Recommendations:
- Reset L IAPS Circuit Breaker CB1-B6. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
NOTE: Before you open the IAPS circuit breakers, make sure that all Engine FADEC circuit breakers are open. If the Engine FADEC circuit breakers remain closed, Engine Igniters will activate. This can cause injury to persons and damage to equipment. - Reset the Electrical Power of the Aircraft. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Swap Left IOC with right IOC. Is the fault message still present?
- If YES, continue with next step.
- If NO, replace defective IOC.
- Contact CRC for failure reporting and additional troubleshooting procedure.