02/16/21
Message Overview:
Message Description:
L-IOC-3 data absent at L-FGC.
Possible Causes:
- Right Input/Output Concentrator Unit (IOC) 2 (A4-IOC)
- Right Flight Guidance Computer (FGC) 2 (A4-FGC)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
Troubleshooting Recommendations:
- Reset R IAPS Circuit Breaker CB2-B6. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
NOTE: Before you open the IAPS circuit breakers, make sure that all Engine FADEC circuit breakers are open. If the Engine FADEC circuit breakers remain closed, Engine Igniters will activate. This can cause injury to persons and damage to equipment. - Swap right IOC with left IOC. Is the fault message still present.
- If YES, continue with next step.
- If NO, replace defective IOC.
- Swap right FGC with left FGC. Is the fault message still present.
- If YES, continue with next step.
- If NO, replace defective FGC.
- Replace Integrated Avionics-Processor System (IAPS) Card Cage (ICC) (A4).
- Do close out.