02/16/21
Message Overview:
Message Description:
Overheat condition for the right IAPS PWR is being reported by left IOC.
Possible Causes:
- Right Integrated-Avionics Processor System (IAPS) Power Supply (PWR 2) (A4-PWR)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Integrated Avionics Processor System (IAPS) Power Supply (PWR) | AMM 31-45-09-000-801 |
| Installation of the Integrated Avionics Processor System (IAPS) Power Supply (PWR) | AMM 31-45-09-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset L IAPS Circuit Breaker CB1-B6, R IAPS Circuit Breaker CB2-B6. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
NOTE: Before you open the IAPS circuit breakers, make sure that all Engine FADEC circuit breakers are open. If the Engine FADEC circuit breakers remain closed, Engine Igniters will activate. This can cause injury to persons and damage to equipment. - Swap the right IAPS PWR with left IAPS PWR. Is the fault message still present?
- If YES, continue with next step.
- If NO, replace defective IAPS PWR.
- Replace IAPS card cage (A4).
- Do close out.