Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/16/21

Message Overview:

Message Name:

OVERHEATED

Message Code:

B3-007549

Associated CAS:

None

Reporting LRU: IAPS PWR 2
System Description: 31-45-00
Schematic Diagram: 31-45-00
Wiring Diagram: 31-45-09

Message Description:

Overheat condition for the right IAPS PWR is being reported by left IOC.

Possible Causes:

  • Right Integrated-Avionics Processor System (IAPS) Power Supply (PWR 2) (A4-PWR)
  • Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Integrated Avionics Processor System (IAPS) Card Cage (ICC) AMM 31-45-01-000-801
Installation of the Integrated Avionics Processor System (IAPS) Card Cage (ICC) AMM 31-45-01-400-801
Removal of the Integrated Avionics Processor System (IAPS) Power Supply (PWR) AMM 31-45-09-000-801
Installation of the Integrated Avionics Processor System (IAPS) Power Supply (PWR) AMM 31-45-09-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. Reset L IAPS Circuit Breaker CB1-B6, R IAPS Circuit Breaker CB2-B6. Is the fault message still present?
    1. If YES, continue with next step.
    2. If NO, do close out.
      NOTE: Before you open the IAPS circuit breakers, make sure that all Engine FADEC circuit breakers are open. If the Engine FADEC circuit breakers remain closed, Engine Igniters will activate. This can cause injury to persons and damage to equipment.

  2. Swap the right IAPS PWR with left IAPS PWR. Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace defective IAPS PWR.

  3. Replace IAPS card cage (A4).
  4. Do close out.