Message Overview:
Message Name:
CSU 1 / CSU 2 MISCOMPARE
Message Code:
B3-405655
Associated CAS:
| Reporting LRU: | CSU 1 / CSU 2 |
| System Description: | 31-45-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
Configuration Strapping Unit 1 data and Configuration Strapping Unit 2 data are reported different by the Maintenance Diagnostic Computer.
Possible Causes:
- Options Control Module (OCM) (on A4CSU)
- Configuration Strapping Unit (CSU) (A4CSU)
- Input/Output Concentrator Unit (IOC) (A4IOC)
- Integrated Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Strapping for CSU 1 & 2 can be compared by simultaneously looking at CSU DATA (LEFT) and CSU DATA (RIGHT) on the MDC CONFIGURATION DATA page.
The OCM provides protected strapping for the 16-bits of word 0.
Quick Links:
| Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Removal of the Configuration Strapping Unit (CSU) | AMM 31-45-17-000-801 |
| Configuration Setting of the Configuration Strapping Unit (CSU) | AMM 31-45-17-280-801 |
| Installation of the Configuration Strapping Unit (CSU) | AMM 31-45-17-400-801 |
| Removal of the Options Control Module (OCM) | AMM 31-45-21-000-801 |
| Installation of the Options Control Module (OCM) | AMM 31-45-21-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do the Configuration Setting of the Configuration Strapping Unit. Re-configure as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap OCMs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap CSUs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap IOCs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace IAPS Card Cage.
- Do close out.