background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

12/19/22

Message Overview:

Message Name:

SATELLITE DATA UNIT

Message Code:

B3-007978

Associated CAS:

None

Reporting LRU: SAT 2X00
System Description: 23-15-00
Schematic Diagram: 23-15-00-101 - SATELLITE COMMUNICATION
Wiring Diagram: 23-15-01-1 - SATCOM Satellite Data Unit (SDU)

Message Description:

One of the following problems exist: Internal Fail, Mod Synth Lock, RFU RX or HPA TX Gain, HSR, HPA, Secure ORT invalid, TX gain, or RFU TX Gain failure.

Possible Causes:

  • Satellite Data Unit (SDU) (A82)
  • Owner Requirements Table (ORT)
  • LNA Duplexer (A83)
  • Satcom Antenna (E24)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Fault Confirmation Procedure:

  1. Message# = 3
  2. Fault Logged = AIR,TAXI
  3. Status = FAILED/WIRING
  4. {Term Definitions}

    1. SRT1-1 XX 350 00 EXCT XXXX-XXXX XXXX-XXXX XXXX-XTXX 350: 11;SDU INTERNAL FAULT
    2. SRT1-6 XX 350 00 EXCT XXXX-XXXX XXXT-XXXX XXXX-XXXX 350: 21;INTER GAIN OR T/P ANTENNA
    3. SRT1-7 XX 350 00 EXCT XXXX-XXXX XXTX-XXXX XXXX-XXXX 350: 22;STARBOARD HI G ANT

Quick Links:

Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. One of the following problems exist: Internal Fail, Mod Synth Lock, RFU RX or HPA TX Gain, HSR, HPA, Secure ORT invalid, TX gain, or RFU_TX_Gain failure.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.