02/24/21
Message Overview:
Message Description:
Internal failure reported by third VHF.
Possible Causes:
- Third VHF Communication Unit (VHF 3) (A10)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the VHF Communication Unit | AMM 23-11-01-000-801 |
| Installation of the VHF Communication Unit | AMM 23-11-01-400-801 |
Troubleshooting Recommendations:
- Reset VHF 3 Circuit Breaker CB3-E2. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace third VHF (A10).
NOTE: Depending on the parts installed, swap test is possible to confirm failure. Verify interchangeability in AIPC 23-11-01 before proceeding. - Do close out.