05/06/21
Message Overview:
Message Description:
CVR is reporting a RIPS (Recorder independent Power Supply) Maint Status Message. Maintenance is required. Detailed Description RIPS Maintenance Discrete Conditions: -The batteries are unbalanced, or -The batteries need to be replaced withing 30 days, or -There is a fault.
Possible Causes:
- Cockpit Voice Recorder (CVR)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 6
- Fault Logged = AIR,TAXI
- Status = FAILED/WIRING
- {Term Definitions}
- CVR1-9 XX 350 00 EXCT XXXX-XXXX XXXX-TXXX XXXX-XXXX 350 :20;RIPS MAINT STATUS(BATTER)
- CVR1-10 XX 350 00 EXCT XXXX-XXXX XXTX-XXXX XXXX-XXXX 350 :22;RIPS PRESENCE STATUS
Quick Links:
| Removal of the Cockpit Voice Recorder (CVR) | AMM 23-71-01-000-801 |
| Installation of the Cockpit Voice Recorder (CVR) | AMM 23-71-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- CVR is reporting a RIPS (Recorder independent Power Supply) Maint Status Message. Maintenance is required.
- Detailed Description RIPS Maintenance Discrete Conditions.
- The batteries are unbalanced.
- The batteries need to be replaced within 30 days.