background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

11/10/23

Message Overview:

Message Name:

SDU OVERHEAT

Message Code:

B3-661656

Associated CAS:

None

Reporting LRU: SAT 2X00
System Description: 23-00-00 - Communication
Schematic Diagram: SSM 23-15-00-101 - Satellite Communication (SATCOM)
SSM 23-15-00-102 - Satellite Communication (SATCOM)
Wiring Diagram: WM 23-15-01-1_001 - Sheet 1 - SATCOM Satellite Data Unit (SDU) - 20501 TO 20960
WM 23-15-09-1_001 - Sheet 1 - SATCOM High Gain Antenna - 20501 TO 20960

Message Description:

Satellite Communications (SATCOM)/Satellite Data Unit (SDU) is reporting SDU OVERTEMP.

Possible Causes:

  • Satellite Communications (SATCOM) Satellite Data Unit (SDU) (A82)
  • Satellite Data Unit (SDU) Mounting Tray
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW300-23-0419 - Satcom Data Unit (SDU-2200) Software Upgrade Available

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Covers and Plugs AMM 10-12-00-020-802
Standard Aircraft Configuration for Maintenance AMM 12-00-00-867-803
Removal of the SATCOM Satellite Data Unit (SDU) AMM 23-15-01-000-801
Installation of the SATCOM Satellite Data Unit (SDU) AMM 23-15-01-400-801
Removal of the SATCOM Satellite Data Unit (SDU) mounting tray AMM 23-15-05-000-801
Installation of the SATCOM Satellite Data Unit (SDU) mounting tray AMM 23-15-05-400-801
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801
Electrostatic-Discharge Safety Precautions AMM 24-00-00-910-802
Connect Electrical Power to the Aircraft AMM 24-00-00-861-801
Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802
Data Download from the Maintenance Diagnostic Computer (MDC) AMM 45-45-01-970-802
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Confirm SATCOM FAN is operating correctly and air flow is passing through SDU venting holes.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. Confirm presence of 28 VDC and grounds at SATCOM FAN connector B195P1.

    1. If power and grounds are present, go to step 6.
    2. If power is not present, go to step 4.
    3. If grounds are not present, continue with next step.

  3. Repair ground wiring and/or ground stud.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  4. Do the wiring check from R DCPC connector A36P4 to SATCOM FAN connector B195P1. Repair/replace as required.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  5. Replace SDU mounting tray.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  6. Replace SDU.
  7. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.